The Infona portal uses cookies, i.e. strings of text saved by a browser on the user's device. The portal can access those files and use them to remember the user's data, such as their chosen settings (screen view, interface language, etc.), or their login data. By using the Infona portal the user accepts automatic saving and using this information for portal operation purposes. More information on the subject can be found in the Privacy Policy and Terms of Service. By closing this window the user confirms that they have read the information on cookie usage, and they accept the privacy policy and the way cookies are used by the portal. You can change the cookie settings in your browser.
Competitive electrochemical enzyme-linked immunosorbent assays based on disposable screen-printed electrodes have been developed for quantitative determination of ochratoxin A (OTA). The assays were carried out using monoclonal antibodies in the direct and indirect format. OTA working range, I 50 and detection limits were 0.05–2.5 and 0.1–7.5μgL −1 , 0.35 (±0.04) μgL −1 and...
This paper reports on a microfluidic device for the flow-injection/electrochemistry analysis of nitroaromatic explosive. The response is very fast (150assays/h), highly sensitive (detection limit 7.0μgL −1 ), reproducible and stable (R.S.D.=2.0%; n=30) and linear (over 20–100μgL −1 range). Relevant experimental parameters have been optimized. The new microsystem offers great promise...
A frequency-selective absorbance detection approach and its applications are described. First, a digital signal processor–lock-in amplifier (DSP–LIA)-based absorbance detector was evaluated. Compared to a simple operational amplifier (TL082CP)-based detector, the DSP–LIA-based detector showed lower noise levels, but the relative advantage was reduced under very low photocurrent levels (down to few...
Spectrophotometric determination of molybdenum(VI) and tungsten(VI) with application of Artificial Neural Networks is proposed and it was applied for elemental analysis of solid polyoxometalates. Better results in comparison with previously those achieved by previous published method were demonstrated. MALDI–TOF Mass Spectrometry was tested for possible determination of molecular weight of polyoxometalates...
Dichlorodiphenyltrichloroethane (DDT) and its metabolites are a typical kind of persistent organic pollutants (POPs). Development of a simple, cost-effective and sensitive methodology to monitor DDTs concentrations in water environment is of particular significance for understanding the fate and behavior of these pollutants. In this paper, a method on the basis of solid-phase extraction (SPE) using...
Recently, two new immobilized polysaccharides based CSPs, namely tris-(3,5-dimethylphenylcarbamate) derivatives of amylose and cellulose known as Chiralpak IA and Chiralpak IB were introduced, which may be used with a wide range of solvents including standard and prohibited ones. Several racemic piperidine-2,6-dione analogues [aminoglutethimide, p-nitro-glutethimide, p-nitro-5-aminoglutethimide, cyclohexylaminoglutethimide,...
This work assesses the potential of a new adsorptive material, Amberlyst 36, for the separation and preconcentration of trace manganese(II) from various media. It is based on the sorption of manganese(II) ions onto a column filled with Amberlyst 36 cation exchange resin, followed by the elution with 5mL of 3mol/L nitric acid and determination by flame atomic absorption spectrometry (FAAS) without...
Unmodified and modified gold nanoparticles are proposed as sensors using the red to blue transition as an indicator. This work indicates that ionic content is an important variable to track in analytical samples and during the sensor fabrication processes. Mono and multivalent salts where the titrants for a standard gold nanoparticle solution. Multivalent cation salt titrants exhibited a greater sensitivity...
Polymerization of metallothioneins (MTs) is one of the commonly encountered puzzles in researching the structure and function of metallothioneins. In this work, a method involving SEC coupled with negative ion electrospray ionization mass spectrometry (ESI-MS) detection has been developed for the study of zinc binding MTs’ polymerization in tris(hydroxymethyl)-aminomethane (TRIS) acetate buffer at...
C 60 -modified glassy carbon electrode has been found to exhibit excellent electrocatalytic activity towards atenolol oxidation for its voltammetric determination at physiological pH. Lowering of overpotential associated with atenolol oxidation indicates electrocatalytic nature of electrode. Determination of atenolol was carried out at pH 7.2 at modified electrode and a well-defined oxidation...
The novel approach using a slope of correlation line (laser-enhanced ionization of lithium versus laser-induced plasma emission of aluminum) as analytical signal was proposed for reduction of matrix interferences in laser-enhanced ionization spectrometric determination of Li with laser sampling.
The analytical applications of the evolved gas analysis (EGA) performed by mass spectrometry, for the period extending from 2001 to 2004, are collected in this review. By this technique, the nature of volatile products released by a substance subjected to a controlled temperature program is on-line determined, with the possibility to prove a supposed reaction, either under isothermal or under heating...
This work has evaluated the influence of humic acid and/or surfactants in the quantification of ammonium in waters with the indophenol-type reaction method. Thymol has been employed with the colorimetric method for sample ammonium concentrations between 0.25 and 1mgL −1 . In addition, SPE/diffuse reflectance method has been used for quantification of ammonium at low concentrations (between...
A simple chemiluminometric method using flow injection has been developed for the determination of paracetamol (acetaminophen), based on the chemiluminescence produced by the reduction of tris(2,2′-bipyridyl)ruthenium(III). The latter is obtained by oxidation of tris(2,2′-bipyridyl)ruthenium(II) by potassium permanganate in dilute sulphuric acid in the presence of paracetamol. A standard or sample...
An integrated light emitting diode (LED)-induced fluorescence detector was described and evaluated. The LED and its related components including lens and interference filter, the optical fiber used to collect fluorescence, and the capillary column are integrated into a substrate block, which eliminates the need of align procedure of the fiber and the capillary. Forty-fold enhancement of sensitivity...
A simple flow injection colourimetric procedure for determining andrographolide was proposed. It is based on the reaction between andrographolide with 3,5-dinitrobenzoic acid, resulting in an intense purplish red complex with a suitable absorption at 536nm. A standard or sample solution was injected into the 3,5-dinitrobenzoic acid stream (flow rate of 1.0mlmin −1 ) which was then merged with...
Bismuth-coated glassy carbon electrodes have been successfully applied for catalytic adsorptive stripping voltammetric measurements of low levels of vanadium(V) in the presence of chloranilic acid (CAA) and bromate ion. The new protocol is based on the accumulation of the vanadium-chloranilic acid complex from an acetate buffer (pH 5.5) solution at a preplated bismuth film electrode held at −0.35V...
This work presents a simple, reproducible and low cost method, employing differential pulse anodic stripping voltammetry, for determination of selenium(IV). A gold electrode obtained from recordable compact disks (CD-R) was used to evaluate the voltammetric behavior of the metallic ion in 0.1molL −1 HClO 4 . To evaluate the voltammetric behavior of Se(IV), parameters such as deposition...
A sensitive and automated method is presented for the determination of polycyclic aromatic hydrocarbons (PAHs) in airborne particulate matter. The procedure includes extraction of PM10-bound PAHs by accelerated solvent extraction (ASE) followed by gel permeation chromatography (GPC) clean-up, and large-volume programmable temperature vaporizer (PTV–LV) injection coupled to GC–MS. The limit of detection...
The electrochemical characteristics of a novel all diamond fabricated boron-doped diamond microelectrode array (BDD-MEA) are critically appraised. The voltammetric response of simple electron transfer processes has been investigated and found to generate sigmoidal voltammetric curves. Furthermore, the device has been utilized for various analytical applications including, the direct detection of 4-nitrophenol...
Set the date range to filter the displayed results. You can set a starting date, ending date or both. You can enter the dates manually or choose them from the calendar.